Industry Application
G-Pro 3600
Reliable power. Anywhere.
Industry Application
G-Pro 3600
3600W continuous output, 18kW max for 1 second to start high-power tools.
2074Wh LiFePO4 battery. Long lifecycle, stable and safe.
Aluminum housing with protective frame. IP54 dust & splash resistant.
Over-voltage, over-current, short-circuit, over-temperature and low-temperature protection.
AC, USB, DC outputs for multiple devices and tools.
Ergonomic handles and compact design for easy transport.
Industry Application
G-Pro 3600
| PARAMETER | SPECIFICATION |
|---|---|
| Model | G-Pro 3600 |
| Battery Type | LiFePO4 |
| Battery Capacity | 2074Wh (40Ah / 51.84V) |
| AC Output | 230VAC, 50Hz, 3600W Continuous, 16A |
| AC Max Power (1s) | 18kW |
| DC Output | 12V / 10A |
| USB-A Output | 5V / 2.4A (x2) |
| USB-C Output | 5V / 3A (15W) (x2) |
| Input (Anderson) | 12-60V / 20A Max |
| AC Charging Input | 90-264VAC, 40-70Hz, 750-1500W |
| Protection | Over-voltage, Over-current, Short-circuit, Over-temperature, Low-temperature |
| IP Rating | IP54 |
| Certification | CE, RoHS |
| Operating Temperature | Charging: 0°C ~ +45°C / Discharging: -20°C ~ +45°C |
| Storage Temperature | -20°C ~ +45°C |
| Dimensions (L×W×H) | 437 × 169 × 475 mm |
| Net Weight | 20.4 kg |
Note: Data for reference only. Actual runtime may vary based on load, temperature and usage.
Industry Application
G-Pro 3600
3 Lighting Modes (High / Low / SOS)
230V ~ 16A Max
12V / 10A
5V / 2.4A
5V / 3A (15W)
12-60V / 20A Max
Intelligent temperature control
Maßzeichnung
437 mm
169 mm
475 mm
Length: 478 mm
Width: 176 mm
Height: 405 mm
Note: All specifications are subject to change without notice. Please refer to the user manual for detailed instructions.
For more information, please contact: eric.xia@gmeoh.de
Industry Application
G-Pro 3600
Press to turn on discharge mode (230V AC output). Press when on to turn off. Long press during charging enables EPS/UPS function.
8 RGB LED lights in circular arrangement showing battery level (green = normal, 8 lights = 100% SOC, each light = 12.5% change). Also indicates fault status.
Connect AC-powered devices. Two sockets wired in parallel, total rated output not exceeding 3600W.
6×30mm, 40A/250V glass fuse (F40AL250V fuse tube) for input protection.
Waterproof CAN communication terminal, normally sealed. Used for multi-unit parallel operation / software debugging and upgrades.
Connect included charging cable for 90~263V/50Hz/60Hz AC charging, maximum charging current 6A.
Live
(Red)
Neutral
(Black)
Ground
(Yellow-Green)
Automatic charging starts when AC power is connected. No button press required.
For multi-unit parallel operation and software interface. Minimum 2 units supported, high current sharing precision.
Industry Application
G-Pro 3600
Normal operation shows green lights (8 lights fully lit = SOC 100%, each light represents 12.5% change). Fault conditions are indicated as follows:
| LED Pattern | Cause | Action Required |
|---|---|---|
| CHARGING STATE ABNORMAL | ||
| Red blinking, 1s interval | MOS overtemperature | Stop charging, restart after temperature normalizes |
| Red-Green blinking, 1s interval | Heatsink overtemperature | Stop charging, restart after temperature normalizes |
| Red-Blue blinking, 1s interval | Cell charging overtemperature | Stop charging, restart after temperature normalizes |
| Blue blinking, 1s interval | Cell charging undertemperature | Stop charging, restart after temperature normalizes |
| RGB blinking, 1s interval | Charging overcurrent | Stop charging (check if bypass load is excessive) |
| Green blinking, 1s interval | Charging input undervoltage | Stop charging, restart after voltage normalizes |
| Blue-Green blinking, 1s interval | Charging input overvoltage | Stop charging, restart after voltage normalizes |
| Red solid | Cell overvoltage | Automatic charging shutdown |
| DISCHARGE STATE ABNORMAL | ||
| Auto shutdown | Cell undervoltage | Automatic shutdown, charging required |
| Auto shutdown | MOS overtemperature | Auto shutdown, can restart after temperature normalizes |
| Auto shutdown | Cell discharge overtemperature | Auto shutdown, can restart after temperature normalizes |
| Auto shutdown | Cell discharge undertemperature | Auto shutdown, can restart after temperature normalizes |
| Auto shutdown | Heatsink overtemperature | Auto shutdown, can restart after temperature normalizes |
| Auto shutdown | Overload/Overcurrent/Short circuit | Auto shutdown, eliminate load fault then restart |
Protection Point: 80VAC
Recovery Point: 85VAC
Hysteresis: 5VAC
Protection Point: 270VAC
Recovery Point: 260VAC
Hysteresis: 10VAC
Protection Point: 10A
Recovery: Auto-recovery
Overcurrent Point: 130A @ 230VAC
Action: Shutdown protection
Power: 5,400W
Duration: > 500 Seconds
Power: 7,200W
Duration: > 50 Seconds
Power: 9,000W
Duration: > 10 Seconds
Power: 18,000W
Duration: > 1 Second
The power station features overtemperature protection with three temperature detection points. When any temperature sensor reaches 100°C, the unit will stop operation and enter overtemperature protection mode. When monitored temperature recovers to 90°C, the power station automatically restarts operation.
Industry Application
G-Pro 3600
This power station meets the following safety standards:
Round-Trip Efficiency at various load levels:
Power Factor: ≥0.98 (>1200W load)
THD: ≤8% @ 1000W and above
Products are individually packaged and shipped in full boxes. Standard packaging ensures protection during transit.
Suitable for vehicle, ship, and air transportation. Keep covered and protected from sunlight during transit. Handle with care.
Store in original packaging. Maintain specified temperature and humidity. Keep away from harmful gases, flammable/explosive materials, and corrosive chemicals.
Grand Power (Shanghai) Electronics Technology Co., Ltd.
Email: eric.xia@gmeoh.de
Website: www.greenmeoh.com